refrigerated circulator – LNEYA Chillers https://www.lneyachillers.com -Air Cooled Chillers Manufacturer; Water-Cooled Chillers Manufacturer;Industrial Chillers; Recirculating Chillers Wed, 12 Apr 2023 06:23:17 +0000 zh-Hans hourly 1 https://wordpress.org/?v=6.8.2 https://www.lneyachillers.com/wp-content/uploads/2022/11/cropped-logo-150-32x32.png refrigerated circulator – LNEYA Chillers https://www.lneyachillers.com 32 32 LT -80℃~-20℃ https://www.lneyachillers.com/lt-80-refrigerated-circulator.html https://www.lneyachillers.com/lt-80-refrigerated-circulator.html#respond Wed, 16 Nov 2022 07:37:10 +0000 https://www.lneyachillers.com/?p=642
LT -80℃~-20℃

LT -80℃~-20℃ Refrigerated Circulator

It can guarantee 24-hour continuous operation
  • Cooling capacity0.2kW~6kW
  • Power range3.5kW~11.5kW
  • Liquid storage15L~60L
  • RefrigerantR404A/R508B
  • Weight185KG~470KG
  • Details
  • Place of OriginChina

Parameters Detailed

1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources

2. Circulating pipeline design, prolong the use time of circulating water

3. Adopt brand compressor, cascade subcooling refrigeration technology

4. Dual Condensing High Efficiency System

5. Computer cascade temperature controller, temperature digital display, adjustment unit 0.1℃

6. Adopt supercooling technology to ensure temperature stability at low temperature

7. It can be set to turn on the compressor and turn off the compressor temperature difference

Configuration Details

Model LT-8018N LT-8030N LT-8062N LT-8090N LT-80A1N LT-80A2WN
Medium Temperature Range  -75℃~-20℃  -80℃~-20℃
Cooling Capacity -60℃ 0.4KW 0.8KW 1.6KW 2.1KW 4KW 6KW
  -75℃ 0.2KW 0.5KW 0.9KW 1.2KW 2KW 3KW
Circulation Pump Flow Rate, Pressure  (max)  20L/min
0.7BAR
20L/min
0.7BAR
35L/min 
1BAR
35L/min
1BAR
75L/min
1BAR
75L/min
1BAR
Capacity of Liquid Storage  15L 20L 30L 35L 40L 60L
Compressor Tecumseh, Dorin
Evaporator Plate Heat Exchanger
Operation Panel 7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A/R23 mixed refrigerant
Connection Size ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1
Product size(air-cooled)(cm) 55*70*175 55*70*175 65*85*185 70*85*185 70*85*185 80*120*185
Weight (air-cooled) 185kg 230kg 275kg 340kg 380kg 470kg
Power 50HZ       
max
AC220V 
3.5kW
AC380V 
4.5kW
AC380V
6.5kW
AC380V
8kW
AC380V
12kW
AC380V
14.5kW
Shell Material Cold rolled sheet spray molding (standard color 7035)
Optional Circulation pump 35L/min  2.5bar、50L/min  2.5bar、110L/min  2.5bar optional
Optional Pressure ≤6 bar circulating pump
Optional  MODBUS RTU Protocol, RS 485 Interface
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,440-480V 60HZ three-phases
Remark Can make the bigger capacity of liquid storage as required.

Working Principle

Widely used in petrochemical industry, pharmaceutical and medical treatment, biochemical engineering, biological freeze-drying, aerospace industry, semiconductor manufacturing, university research institutes and other high-tech industries.

Supporting equipment: provide cold source for production process of various reactors, vacuum chambers, experimental instruments, microchannels, etc., and also cool semiconductor equipment, mechanical equipment, dryers, evaporators, etc;

This model is a air-cooled chiller. Use the mixture of ethylene glycol and water for circulating cooling.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/lt-80-refrigerated-circulator.html/feed 0
LT -60℃~-20℃ https://www.lneyachillers.com/lt-60-air-cooled-chiller.html https://www.lneyachillers.com/lt-60-air-cooled-chiller.html#respond Wed, 16 Nov 2022 07:27:00 +0000 https://www.lneyachillers.com/?p=640
LT -60℃~-20℃
LT -60℃~-20℃
LT -60℃~-20℃
LT -60℃~-20℃
LT -60℃~-20℃

LT -60℃~-20℃ Air cooled chiller

It can guarantee 24-hour continuous operation
  • Cooling capacity0.4kW~6kW
  • Power range3kW~9kW
  • Liquid storage15L~60L
  • RefrigerantR404A/R23
  • Weight145KG~380KG
  • Details
  • Place of OriginChina

Parameters Detailed

1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources

2. Circulating pipeline design, prolong the use time of circulating water

3. Adopt brand compressor, cascade subcooling refrigeration technology

4. Dual Condensing High Efficiency System

5. Computer cascade temperature controller, temperature digital display, adjustment unit 0.1℃

6. Adopt supercooling technology to ensure temperature stability at low temperature

7. It can be set to turn on the compressor and turn off the compressor temperature difference

Configuration Details

Model LT-6518N LT-6530N LT-6562N LT-6590N LT-65A1N LT-65A2WN
Medium Temperature Range  -60℃~-20℃
Cooling Capacity              
  -40℃ 0.7KW 1.2KW 2.1KW 2.8KW 4KW 6KW
  -60℃ 0.4KW 0.6KW 1.2KW 1.6KW 2KW 3KW
Circulation Pump Flow Rate, Pressure  (max)  20L/min
0.7BAR
20L/min
0.7BAR
35L/min 
1BAR
35L/min
1BAR
75L/min
1BAR
75L/min
1BAR
Capacity of Liquid Storage  15L 20L 30L 35L 40L 60L
Compressor Tecumseh, Dorin
Evaporator Plate Heat Exchanger
Operation Panel 7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A/R23
Connection Size ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1
Product size(air-cooled)(cm) 55*70*175 55*70*175 55*70*175 65*85*185 70*85*185 70*85*185
Weight (air-cooled) 145KG 185kg 230kg 275kg 340kg 380kg
Power 50HZ       
max
AC220V
2.6kW
AC380V
3.5kW
AC380V
5kW
AC380V
8kW
AC380V
9kW
AC380V
11kW
Shell Material Cold rolled steel painting
Optional Circulation pump  35L/min  2.5bar、50L/min  2.5bar、110L/min  2.5bar optional
Optional Pressure ≤6 bar circulating pump
Optional MODBUS RTU Protocol, RS 485 Interface
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,460V 60HZ three-phases
Remark Can make the bigger capacity of liquid storage as required.

Working Principle

Widely used in petrochemical industry, pharmaceutical and medical treatment, biochemical engineering, biological freeze-drying, aerospace industry, semiconductor manufacturing, university research institutes and other high-tech industries.

Supporting equipment: provide cold source for production process of various reactors, vacuum chambers, experimental instruments, microchannels, etc., and also cool semiconductor equipment, mechanical equipment, dryers, evaporators, etc;

This model is a air-cooled chiller. Use the mixture of ethylene glycol and water for circulating cooling.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/lt-60-air-cooled-chiller.html/feed 0
LT -45℃~-30℃ https://www.lneyachillers.com/lt-45-refrigerated-circulator.html https://www.lneyachillers.com/lt-45-refrigerated-circulator.html#respond Wed, 16 Nov 2022 07:17:49 +0000 https://www.lneyachillers.com/?p=637
LT -45℃~-30℃
LT -45℃~-30℃
LT -45℃~-30℃
LT -45℃~-30℃
LT -45℃~-30℃

LT -45℃~30℃ refrigerated circulator

Saving water resources & circulating cooling
  • Cooling capacity0.75kW~12kW
  • Power range1.6kW~8kW
  • Liquid storage15L~80L
  • RefrigerantR404A/R507C
  • Weight145KG~380KG
  • Details
  • Place of OriginChina

Parameters Detailed

1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resource

2. Circulating pipeline design, prolong the use time of circulating water

3. Adopt brand compressor, cascade subcooling refrigeration technology

4. Dual Condensing High Efficiency System

5. Computer cascade temperature controller, temperature digital display, adjustment unit 0.1℃

6. Adopt supercooling technology to ensure temperature stability at low temperature

7. It can be set to turn on the compressor and turn off the compressor temperature difference

Configuration Details

Model LT-5018N LT-5040N LT-5062N LT-5090N LT-50A1N LT-50A2N
Medium Temperature Range  -37℃~30℃  -45℃~30℃
Cooling Capacity -10℃ 1.5KW 3.2KW 4.5KW 6.2KW 8.3KW 12KW
  -20℃ 1.2KW 2.7KW 3.8KW 5.5KW 7KW 10KW
  -40℃   0.75KW 1.15KW 1.5KW 2.1KW 3KW
Circulation Pump Flow Rate, Pressure  (max)  20L/min
0.7BAR
20L/min
0.7BAR
35L/min
1BAR
35L/min
1BAR
50L/min
1BAR
50L/min
1BAR
Capacity of Liquid Storage  15L 20L 25L 30L 50L 80L
Compressor Tecumseh, Emerson Copeland, Danfoss
Evaporator Plate Heat Exchanger
Operation Panel 7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A/R507C
Connection Size ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Product size(air-cooled)(cm) 40*70*130 45*70*160 45*70*160 55*70*175 65*85*185 70*85*185
Weight (air-cooled) 145KG 185kg 230kg 275kg 340kg 380kg
Power 50HZ       
max
AC220V
1.5kW
AC380V
2kW
AC380V
3.5kW
AC380V
4.5kW
AC380V 
6kW
AC380V
8kW
Shell Material Cold rolled sheet spray molding (standard color 7035)
Optional Pressure ≤6 bar circulating pump
Optional MODBUS RTU Protocol, RS 485 Interface
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,460V 60HZ three-phases
Remark Can make the bigger capacity of liquid storage as required.

Working Principle

Widely used in petrochemical industry, pharmaceutical and medical treatment, biochemical engineering, biological freeze-drying, aerospace industry, semiconductor manufacturing, university research institutes and other high-tech industries.

Supporting equipment: provide cold source for production process of various reactors, vacuum chambers, experimental instruments, microchannels, etc., and also cool semiconductor equipment, mechanical equipment, dryers, evaporators, etc;

This model is a air-cooled chiller. Use the mixture of ethylene glycol and water for circulating cooling.

RELATED PRODUCTS

Switch more

loading…

No more to see

WordPress简介和历史以及近年来的发展

WordPress是使用PHP语言开发的博客平台,用户可以在支持PHP和MySQL数据库的服务器上架设属于自己的网站。也可以把 WordPress当作一个内容管理系统(CMS)来使用。

WordPress是一款个人博客系统,并逐步演化成一款内容管理系统软件,WordPress目前在全世界网站的占有率已经超过40%,是目前全球最流行的开源网页项目之一。

WordPress简介和历史以及近年来的发展

WordPress是使用PHP语言开发的博客平台,用户可以在支持PHP和MySQL数据库的服务器上架设属于自己的网站。也可以把 WordPress当作一个内容管理系统(CMS)来使用。

WordPress是一款个人博客系统,并逐步演化成一款内容管理系统软件,WordPress目前在全世界网站的占有率已经超过40%,是目前全球最流行的开源网页项目之一。

]]>
https://www.lneyachillers.com/lt-45-refrigerated-circulator.html/feed 0
LX -25℃~-30℃ https://www.lneyachillers.com/lx-air-cooled-chiller.html https://www.lneyachillers.com/lx-air-cooled-chiller.html#respond Wed, 16 Nov 2022 07:06:04 +0000 https://www.lneyachillers.com/?p=635
LX -25℃~-30℃
LX -25℃~-30℃
LX -25℃~-30℃
LX -25℃~-30℃
LX -25℃~-30℃

LX -25℃~30℃ Low Temperature Chiller

Saving water resources & circulating cooling
  • Cooling capacity0.8kW~30kW
  • Power range1.5kW~17kW
  • Liquid storage15L~300L
  • RefrigerantR404A
  • Weight115KG~950KG
  • Details
  • Place of OriginChina

Parameters Detailed

  • Can use ethylene glycol mixed with water for circulating refrigeration, saving resources
  • Circulating pipeline design, prolong the use time of circulating water
  • Adopt brand compressor, cascade subcooling refrigeration technology
  • Dual Condensing High Efficiency System
  • Computer cascade temperature controller, temperature digital display, adjustment unit 0.1℃
  • Adopt supercooling technology to ensure temperature stability at low temperature
  • It can be set to turn on the compressor and turn off the compressor temperature difference

Configuration Details

Model LX-0250N LX-0400N LX-0700N LX-1000N LX-1450N LX-2000N LX-2600N LX-3500N LX-5000N
Medium Temperature Range  -25℃~30℃
Temp. Control and Dispaly  PLC multifunctional controller, control outlet temperature of water tank
Temp. Control Optional Temperature feedback PT100 (inlet temperature, outlet temperature)
Cooling Capacity 0℃ 1.5KW 2.4KW 4KW 7.5KW 10KW 15.5KW 20kw 26.5kw 38kw
-10℃ 1KW 1.5KW 2.7KW 6.3KW 8KW 12KW 15.5kw 21kw 30kw
-20℃   0.8KW 1.5KW 3.5KW 5KW 7.3KW 10kw 13.5kw 20kw
Circulation Pump Flow Rate, Pressure  (max)  20L/min 20L/min 35L/min 35L/min 75L/min 75L/min 110L/min 200L/min 250L/min
1.5BAR 1.5BAR 1.2BAR 1.2BAR 1.2BAR1.2 1.2BAR 1.2BAR 1.2BAR 1.2BAR 1.5BAR 1.5BAR
Capacity of Liquid Storage  15L 17L 25L 30L 40L 60L 80L 150L 300L
Compressor Tecumseh Emerson Copeland
Evaporator Plate Heat Exchanger
Operation Panel 7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A/R507C
Connection Size ZG1/2 ZG3/4 ZG1 ZG1 1/4 DN40 PN10
Product size(cm) 40*70*130 40*70*130 45*70*160 55*70*175 65*185*185 65*85*185 80*120*200 100*150*205 145*250*225
Weight (air-cooled) 115KG 145kg 180kg 225kg 290kg 340kg 400kg 650kg 950kg
Power (max )
50hz
AC220V
1.5kW
AC220V
2.2kW
AC220V
2.5kW
AC380V
3.5kW
AC380V
4.5kW
AC380V
7kW
AC380V
9kW
AC380V
12kW
AC380V
 21kW
Shell Material Cold rolled sheet spray molding (standard color 7035)
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,460V 60HZ three-phases

Working Principle

Widely used in petrochemical industry, pharmaceutical and medical treatment, biochemical engineering, biological freeze-drying, aerospace industry, semiconductor manufacturing, university research institutes and other high-tech industries.

Supporting equipment: provide cold source for production process of various reactors, vacuum chambers, experimental instruments, microchannels, etc., and also cool semiconductor equipment, mechanical equipment, dryers, evaporators, etc;

This model is a air-cooled chiller. Use the mixture of ethylene glycol and water for circulating cooling.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/lx-air-cooled-chiller.html/feed 0
LT-115℃~-70℃ https://www.lneyachillers.com/lt-water-cooled-chiller.html https://www.lneyachillers.com/lt-water-cooled-chiller.html#respond Wed, 16 Nov 2022 06:51:15 +0000 https://www.lneyachillers.com/?p=619
LT-115℃~-70℃
LT-115℃~-70℃
LT-115℃~-70℃
LT-115℃~-70℃
LT-115℃~-70℃

LT-115℃~-70℃ water cooled chiller

Saving water resources & circulating cooling
  • Cooling capacity0.3kW~2.1kW
  • Power range5.5kW~14kW
  • Liquid storage15L~40L
  • RefrigerantR404A/R23/R14
  • Weight235KG~480KG
  • Details
  • Place of OriginChina

Parameters Detailed

1.Can use ethylene glycol mixed with water for circulating refrigeration, saving resources

2. Circulating pipeline design, prolong the use time of circulating water

3. Adopt brand compressor, cascade subcooling refrigeration technology

4. Dual Condensing High Efficiency System

5. Computer cascade temperature controller, temperature digital display, adjustment unit 0.1℃

6. Adopt supercooling technology to ensure temperature stability at low temperature

7. It can be set to turn on the compressor and turn off the compressor temperature difference

Configuration Details

Model LT-A025WN LT-A050WN LT-A080WN LT-A215WN LT-A230WN LT-A255WN
Medium Temperature Range -105℃~-60℃  -120℃~-70℃
Temp. Control and Dispaly  PLC multifunctional controller, control outlet temperature of water tank
Temp. Control Optional Temperature feedback PT100 (inlet temperature, outlet temperature)
Cooling Capacity
-75℃ 1.3KW 3KW 5KW      
-95℃ 0.7KW 1.4KW 2.3KW 0.7KW 1.4KW 2.1KW
-110℃       0.3KW 0.55KW 0.95KW
Circulation Pump Flow Rate, Pressure  (max)  20L/min
0.7BAR
35L/min
1BAR
75L/min 
1BAR
20L/min
0.7BAR
35L/min
1BAR
35L/min
1BAR
Capacity of Liquid Storage  15L 25L 40L 15L 25L 40L
Compressor Tecumseh, Dorin
Evaporator Plate Heat Exchanger
Operation Panel 7-inch color touch screen shows setting temperature and measuring temperature, temperature curve record,  data export excel-format
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch;overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A\R23\R14
Connection Size ZG1/2 ZG3/4 ZG1 ZG3/4 ZG3/4 ZG3/4
Product size(water-cooled)(cm) 80*120*185 100*150*185 100*150*185 80*120*185 80*120*185 100*150*185
Weight (water-cooled) 235kg 320kg 455kg 340kg 380kg 480kg
Power 50HZ       
max
AC380V
5.5kW
AC380V
7.5kW
AC380V
11kW
AC380V
6kW
AC380V
9.5kW
AC380V
14kW
Shell Material Cold rolled sheet spray molding (standard color 7035)
Optional Circulating pump 35L/min  2.5bar、50L/min  2.5bar、110L/min  2.5bar optional
Optional Pressure ≤6 bar circulating pump
Optional  MODBUS RTU Protocol, RS 485 Interface
Optional SUS304 Material
Optional Power 220V 60HZ three-phases,460V 60HZ three-phases
Remark Can make the bigger capacity of liquid storage as required.

Working Principle

1.The basic principle of Ultra-Low Temp. Water-Cooled Chiller is that under ultra-low temperature, the movement of molecules is slowed down until the surface of the trapped and frozen cryogenic coiled tubes is slowed down, and the vapor is easy to be arrested, set and frozen, and the capture rate is high.

2.The secondary supercooling technology is adopted, with rapid refrigeration and low temperature.

Widely used in petrochemical industry, pharmaceutical and medical treatment, biochemical engineering, biological freeze-drying, aerospace industry, semiconductor manufacturing, university research institutes and other high-tech industries.

Supporting equipment: provide cold source for production process of various reactors, vacuum chambers, experimental instruments, microchannels, etc., and also cool semiconductor equipment, mechanical equipment, dryers, evaporators, etc;

This model is a water-cooled chiller. Refrigerant lines and cooling water lines need to be installed.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/lt-water-cooled-chiller.html/feed 0